Selectable Plug-In End Of Line Unit : PEU
Different values of EOL resistances can be instantly set by plugging in optional modules. Please refer to the relevant control panels manual to confirm matching resistance values.
| Products Name |
|---|
| PEU-B |
| PEU-C |
| PEU-D |
| PEU-E |
| PEU-F |
| PEU-G |
| PEU-H |
| PEU-I |
| PEU-J |
| PEU-K |
Table of model name and resistance values (alarm, trouble and tamper) for control panels
|
Item |
Trouble |
Alarm |
Tamper |
Panels |
|---|---|---|---|---|
|
PEU-B |
6.8K |
4.7K |
4.7K |
Old GE/Aritech |
|
PEU-C |
12.0K |
1.0K |
1.0K |
Honeywell Galaxy (U.K.) |
|
PEU-D |
3.0K |
1.0K |
1.0K |
Honeywell Galaxy (Benelux) |
|
PEU-E |
15.0K |
1.1K |
1.1K |
Satel |
|
PEU-F |
5.6K |
5.6K |
5.6K |
DSC, Ksenia |
|
PEU-G |
8.2K |
8.2K |
8.2K |
Guardall |
|
PEU-H |
2.2K |
4.7K |
2.2K |
Old Texecom, Cooper, Scantronics etc. |
|
PEU-I |
1.0K |
3.3K |
3.3K |
New Texecom, NetworX, Inim |
|
PEU-J |
12.0K |
6.8K |
4.7K |
Risco ProSYS |
|
PEU-K |
2.2K |
1.0K |
1.0K |
Siemens SPC |