Selectable Plug-In End Of Line Unit : PEU
- PEU-B
- PEU-C
- PEU-D
- PEU-E
- PEU-F
- PEU-G
- PEU-H
- PEU-I
- PEU-J
- PEU-K
Different values of EOL resistances can be instantly set by plugging in optional modules. Please refer to the relevant control panels manual to confirm matching resistance values.
Table of model name and resistance values (alarm, trouble and tamper) for control panels
Item |
Trouble |
Alarm |
Tamper |
Panels |
---|---|---|---|---|
PEU-B |
6.8K |
4.7K |
4.7K |
Old GE/Aritech |
PEU-C |
12.0K |
1.0K |
1.0K |
Honeywell Galaxy (U.K.) |
PEU-D |
3.0K |
1.0K |
1.0K |
Honeywell Galaxy (Benelux) |
PEU-E |
15.0K |
1.1K |
1.1K |
Satel |
PEU-F |
5.6K |
5.6K |
5.6K |
DSC, Ksenia |
PEU-G |
8.2K |
8.2K |
8.2K |
Guardall |
PEU-H |
2.2K |
4.7K |
2.2K |
Old Texecom, Cooper, Scantronics etc. |
PEU-I |
1.0K |
3.3K |
3.3K |
New Texecom, NetworX, Inim |
PEU-J |
12.0K |
6.8K |
4.7K |
Risco ProSYS |
PEU-K |
2.2K |
1.0K |
1.0K |
Siemens SPC |