Selectable Plug-In End Of Line Unit : PEU
Different values of EOL resistances can be instantly set by plugging in optional modules. Please refer to the relevant control panels manual to confirm matching resistance values.
Products Name |
---|
PEU-B |
PEU-C |
PEU-D |
PEU-E |
PEU-F |
PEU-G |
PEU-H |
PEU-I |
PEU-J |
PEU-K |
Table of model name and resistance values (alarm, trouble and tamper) for control panels
Item |
Trouble |
Alarm |
Tamper |
Panels |
---|---|---|---|---|
PEU-B |
6.8K |
4.7K |
4.7K |
Old GE/Aritech |
PEU-C |
12.0K |
1.0K |
1.0K |
Honeywell Galaxy (U.K.) |
PEU-D |
3.0K |
1.0K |
1.0K |
Honeywell Galaxy (Benelux) |
PEU-E |
15.0K |
1.1K |
1.1K |
Satel |
PEU-F |
5.6K |
5.6K |
5.6K |
DSC, Ksenia |
PEU-G |
8.2K |
8.2K |
8.2K |
Guardall |
PEU-H |
2.2K |
4.7K |
2.2K |
Old Texecom, Cooper, Scantronics etc. |
PEU-I |
1.0K |
3.3K |
3.3K |
New Texecom, NetworX, Inim |
PEU-J |
12.0K |
6.8K |
4.7K |
Risco ProSYS |
PEU-K |
2.2K |
1.0K |
1.0K |
Siemens SPC |