180 Degree Panoramic Outdoor PIR Detector : WX INFINITY Series

 180 Degree Panoramic Outdoor PIR Detector : WX INFINITY Series

Wired Model

  • WXI-ST[Standard]
  • WXI-AM[Active IR anti-masking]

Battery Operated Model

  • WXI-R[Battery operated]
  • WXI-RAM[Battery operated with active IR anti-masking]

External sensing you can depend upon

The OPTEX WXI series is a family of external sensors built upon our years of proven experience. The series utilizes both analog and digital technologies to detect approaching intruders before they gain access into your protected area. With its comprehensive 180°field of view and capabilities to tailor its setting to meet the environment around your premise, the WXI series will provide an effective solution for new and existing security systems.

Features

  • 180 degree wall-to-wall coverage
  • Individual alarm outputs
  • Individual sensitivity setting
  • Individual detection area size
  • Self-learning IR digital anti-masking function
  • Sunlight canceling
  • Rainwater and insect canceling
  • AND logic function to reduce false alarms
  • Area masking shutter
  • Area masking plate
  • SMDA (Super Multidimensional Analysis) logic

Individual alarm outputs


An installation of a WXI values 2 detectors because it triggers alarm signals both left and right side individually So it’s useful for PTZ activation, direction recognition and changing detection pattern by day and night with a CP.

Individual sensitivity setting


Detection sensitivity can be set to High, Medium and Low by left and right switches individually.

Self-learning IR digital anti-masking function


WXI detects covering objects on lens surface. IR digital anti-masking function optimizes trigger level of trouble outputs generated by masking depends on status of lens surface. A well-calibrated adjustment for both of emitting and receiving level of IR LED fluctuating by temperature contributes to stable anti-masking.

Area masking shutter


By rotary sliding area masking shutter, the size of detection areas can be changed.

Area masking plate


Unwanted detection areas can be masked by included area masking plate.

Screw free design


You can open / close front cover and remove / put main unit without any screws. It contributes to reduction of installation time. And it automatically begins when you close front cover and ends after 3 minutes.

Double conductive shielding


By using our double conductive shielding, the visible light disturbance and RFI can be blocked.

SMDA (Super Multi Dimension Analysis) logic


By analyzing detection patterns and environmental information, SMDA improves immunity against various noise factors such as climate changes and vegetation sways, and can distinguish between the cause of nuisance false alarms and genuine intrusions.

Double-layered detection patterns


Two double-layered detection patterns (upper and lower) both have to be activated to generate an alarm condition. This reduces false alarms, particularly those caused by temperature changes, light reflection and small animals.

Application Examples

Residential
Residential
Rooftop
Rooftop
Substation
Substation

Options

Please go to the support page to get the necessary files in PDF and/or DXF.

  • Coverage

  • Specifications

  • Dimensions

Coverage

Unit(m)

Model WXI-ST WXI-AM WXI-R WXI-RAM
Detection method Passive infrared
Coverage 180° wide
PIR zones Horizontal 14 pairs, vertical 2 layers
PIR distance limit 2.5 to 12 m (Stepless adjustment)
Detectable speed 0.3 to 2.0 m/s (1' to 6'7"/s)
Sensitivity 2.0 °C (3.6°F) at 0.6 m/s Selectable for each side individually
Power input 9.5 – 18 VDC 3 to 3.6 VDC lithium batteries
Current draw 24 mA max. at 12 VDC 23 mA max. at 12 VDC 15 μA stand-by 4 max. at 3 VDC except walk test 16 μA stand-by 4 max. at 3 VDC except walk test
Alarm period 2.0 ±1 sec.
Warm-up period Approx. 60 sec. (LED blinks)
Alarm output (Right) 28 VDC 0.1 A max. [Individual : Right or General], [N.O. or N.C.] are selectable Solid State switch, 10 VDC 0.01 A max. [Individual : Right or General], [N.O. or N.C.] are selectable
Alarm output (Left) 28 VDC 0.1 A max. [Individual : Left or General], [N.O. or N.C.] are selectable Solid State switch, 10 VDC 0.01 A max. [Individual : Left or General], [N.O. or N.C.] are selectable
Trouble output - N.C. 28 VDC 0.1 A max. Solid State switch, 10 VDC 0.01 A max. [N.O. or N.C.] is selectable
Tamper output N.C. 28 VDC 0.1 A max. Open when either the cover, main or base unit is removed Tamper output is shared with trouble output.
LED indicator (DIP switch ON or Walk test) Red LED : 1. Warm-up 2. Alarm Red LED : 1. Warm-up 2. Alarm 3. Masking detection Red LED : 1. Warm-up 2. Alarm Red LED : 1. Warm-up 2. Alarm 3. Masking detection
Operating temperature -30 °C to +60 °C (-22°F to +140°F) -30 °C to +60 °C (-22°F to +140°F) except batteries
Environment humidity 95% max.
IP rating IP55
Mounting Wall, Pole (Outdoor, Indoor)
Mounting height 0.8 – 1.2 m (2.64 ft – 3.94 ft)
Weight 420 g (14.8 oz.) 440 g (15.5 oz.) 600 g (21.2 oz.)
Accessories Mounting screw (4 x 20 mm) x 2, lock screw x 1 Connector for POWER and ALARM (R), Connector for ALARM (L) Connector for TROUBLE, Velcro tape Mounting screw (4 x 20 mm) x 2, Lock screw x 1

Battery Life

Model WXI-R WXI-RAM
Interval (sec.) 120 5 120 5
Battery type CR123A (3VDC, 1300 mAh) 5 3.5 5 3.5
CR2 (3VDC, 750 mAh) 3 2 3 2
1/2AA (3.6VDC, 1000 mAh) 4 2.5 4 2.5

Unit: years (approx.)

* Specifications and design are subject to change without prior notice.

Dimensions

Unit(mm)

Contact phone number

Headquarters
+81-77-579-8004

Support information