Boundary Outdoor PIR Detector : BX SHIELD Series
Wired Model
- BXS-ST[Standard]
- BXS-AM[Active IR anti-masking]
Battery Operated Model
- BXS-R[Battery operated]
- BXS-RAM[Battery operated model with active IR anti-masking]
Color variations
-
White
-
Black
Features
- 4 PIR technology
- 24 m (80 ft.) 12 m (40 ft.) on each side adjustable to 5 ranges (2.5 m, 3.5 m, 6.0 m, 8.5 m, 12.0 m)
- Individual detection area and sensitivity setting
- Extreme high detection mode
- SMDA logic for advanced temperature compensation
- Individual signal outputs (right / left)
- Double conductive shielding against bright light disturbance
- Back tamper
- Automatic walk test mode
Application Examples
Options
BXS Face Cover (White / Silver / Black)
Face cover for series
BXS Back Box (White / Black)
Back box for BXS series
BXS Back Box Cap (White / Silver / Black)
Back box cap for BXS series
Coverage
Specifications
Dimensions
Model | BXS-ST | BXS-AM | BXS-R | BXS-RAM |
---|---|---|---|---|
Detection method | Passive infrared | |||
Coverage | 24 m (80') : 12 m (40') on each side, 4 zones : 2 zones on each side, 180°narrow |
|||
PIR distance limit | list the possible range 2.5, 3.5, 6, 8.5, 12 m | 2.5 to 12 m (5 levels) | ||
Detection angle from wall | to Wall : 0°, away Wall : 3°, selectable | |||
Detectable speed | 0.3 to 2.0 m/s (1' to 6'7/s) | |||
Sensitivity | Normal : 2.0°C (3.6°F) at 0.6 m/s
Extreme high : 1.0°C(1.8°F)at 0.6 m/s selectable for each side individually |
|||
Power input | 9.5 to 18 VDC | 3 to 9 VDC Lithium or Alkaline batteries | ||
Current draw (except walk test) | 31 mA max. at 12 VDC | 34 mA max. at 12 VDC | 15 μA stand-by / 8 mA max. at 3 VDC | 16 μA stand-by / 8 mA max. at 3 VDC |
Alarm period | 2.0 ±1 sec. | |||
Warm-up period | 60 sec. or less (LED blinks) | |||
Alarm output (R) | 28 VDC 0.1 A max.,(Idividual : Right or General], (NO. or N.C.) re selectable | Solid State switch, 10 VDC 0.01 A max.,(Individual : Right or General) (N.O. or N.C.) are selectable | ||
Alarm output (L) | 28 VDC 0.1 A max.,(Idividual : Left or General], (NO. or N.C.) re selectable | Solid State switch, 10 VDC 0.01 A max.,(Individual : Left or General) (N.O. or N.C.) are selectable | ||
Trouble output | - | N.C. 28 VDC 0.1 A max. | Solid State switch, 10 VDC 0.01 A max. (N.O. or N.C.) is selectable | |
Tamper output | N.C. 28 VDC 0.1 A max. open when face cover, main unit or base unit is removed | Tamper output is shared with trouble output. | ||
LED indicator | Red LED : 1. Warm-up 2. Alarm (DIP switch ON or Walk test) | Red LED :1. Warm-up 2. Alarm 3. Masking detection (DIP switch ON or Walk test) | Red LED : 1. Warm-up 2. Alarm (DIP switch ON or Walk test) | Red LED : 1. Warm-up 2. Alarm , 3. Masking detection (DIP switch ON or Walk test) |
Operating temperature | -30°C to + 60°C (-22°F to +140°F) | |||
Environment humidity | 95% max. | |||
Operating temperature | -30°C to + 60°C (-22°F to +140°F) | |||
International protection | IP55 | |||
Mounting | Wall, Pole (Outdoor, Indoor) | |||
Mounting height | 0.8 to 1.2 m (2'7" to 4') | |||
Weight | 430 g (15.2 oz.) | 550 g (19.4 oz.) | ||
Accessories | Screw (4 x 20 mm) x 2 | [1] Connector for POWER and ALARM (R), [2] Connector for ALARM (L), [3] Connector for TROUBLE, [4] Velcro tape, [5] Screw (4x20 mm) x 2 |
* Specifications and design are subject to change without prior notice.
BXS-ST/AM
BXS-R/RAM
Unit(mm)
Contact phone number
- Headquarters
- +81-77-579-8004
Contact form
Support information