Compact Outdoor Detector : FTN Series
Wired Model
- FTN-ST[Standard]
- FTN-AM[Active IR anti-masking]
Battery Operated Model
- FTN-R[ Battery operated]
- FTN-RAM[Active IR anti-masking]
FTN Series offers the perfect solution for those outdoor areas where environmental disturbances and small animals may cause false alarms.
Features
- 5 m / 2 m narrow range
- 190° horizontal flexibility
- Enhanced pet immunity
- Super Multi Dimension Analysis Logic
- Double conductive shielding
- Intelligent AND logic
- Active IR digital anti-masking (FTN-AM/RAM only)
- Complete battery operation (FTN-R/RAM only)
Options
Coverage
Specifications
Dimensions
Model |
FTN-ST |
FTN-AM |
FTN-R |
FTN-RAM |
---|---|---|---|---|
Detection method |
Passive infrared |
Passive infrared |
Passive infrared |
Passive infrared |
Coverage |
5×1m (16'5"×3'3") |
5×1m (16'5"×3'3") |
5×1m (16'5"×3'3") |
5×1m (16'5"×3'3") |
Detection length limit |
2 m, 5 m (6'7", 16'5") |
2 m, 5 m (6'7", 16'5") |
2 m, 5 m (6'7", 16'5") |
2 m, 5 m (6'7", 16'5") |
Detectable speed |
0.3 - 1.5 m/s (1' - 4'11"/s) |
0.3 - 1.5 m/s (1' - 4'11"/s) |
0.3 - 1.5 m/s (1' - 4'11"/s) |
0.3 - 1.5 m/s (1' - 4'11"/s) |
Sensitivity |
2.0°C (at 0.6 m/s) (3.6°F (at 2'/s)) |
2.0°C (at 0.6 m/s) (3.6°F (at 2'/s)) |
2.0°C (at 0.6 m/s) (3.6°F (at 2'/s)) |
2.0°C (at 0.6 m/s) (3.6°F (at 2'/s)) |
Operation voltage |
9.5 - 18 VDC |
9.5 - 18 VDC |
2.5 - 10 VDC |
2.5 - 10 VDC |
Power input |
- |
- |
3 - 9 VDC (Lithium or Alkaline Battery) |
3 - 9 VDC (Lithium or Alkaline Battery) |
Current draw |
17 mA (max.) (at 12 VDC) |
20 mA (max.) (at 12 VDC) |
9 μA (at stand-by) / |
10 μA (at stand-by) / |
Alarm period |
2.0 ±1.0 sec. |
2.0 ±1.0 sec. |
2.0 ±1.0 sec. |
2.0 ±1.0 sec. |
Warm-up period |
Approx. 60 sec. (LED blinks) |
Approx. 60 sec. (LED blinks) |
Approx. 120 sec. (LED blinks) |
Approx. 120 sec. (LED blinks) |
Alarm output |
N.C./N.O. Selectable 28 VDC 0.1 A (max.) |
N.C./N.O. Selectable 28 VDC 0.1 A (max.) |
N.C./N.O. Selectable-Solid State Switch 10 VDC 0.01 A (max.) |
N.C./N.O. Selectable-Solid State Switch 10 VDC 0.01 A (max.) |
Trouble output |
N.C. 28 VDC 0.1 A (max.), open when the cover is removed. |
N.C. 28 VDC 0.1 A (max.), open when the cover is removed. |
N.C./N.O. Selectable-Solid State Switch 10 VDC 0.01 A (max.) |
N.C./N.O. Selectable-Solid State Switch 10 VDC 0.01 A (max.) |
LED indicator |
Light/Blink: Warm-up, alarm |
Light/Blink: Warm-up, alarm, masking detection (FTN-AM only) |
Enable: During DIP switch 1 (WALK TEST MODE) or DIP switch 4 (LED) ON |
Enable: During DIP switch 1 (WALK TEST MODE) or DIP switch 4 (LED) ON |
Operation temperature |
20 - +60°C (-4 - +140°F) |
20 - +60°C (-4 - +140°F) |
20 - +60°C (-4 - +140°F) |
20 - +60°C (-4 - +140°F) |
Environment humidity |
95% max. |
95% max. |
95% max. |
95% max. |
Weatherproof |
IP55 |
IP55 |
IP55 |
IP55 |
Mounting |
Wall (Outdoor, Indoor) |
Wall (Outdoor, Indoor) |
Wall (Outdoor, Indoor) |
Wall (Outdoor, Indoor) |
Mounting height |
0.8 - 1.2 m (2'7" - 3'11") |
0.8 - 1.2 m (2'7" - 3'11") |
0.8 - 1.2 m (2'7" - 3'11") |
0.8 - 1.2 m (2'7" - 3'11") |
Weight |
100 g (3.5 oz.) |
100 g (3.5 oz.) |
190 g (6.7 oz.) |
190 g (6.7 oz.) |
Accessories |
screw (3×20 mm)×2 |
screw (3×20 mm)×2 |
Connector for POWER and ALARM, |
Connector for POWER and ALARM, |
Unit(mm)