PIR Detector / PIR Microwave Combination Detector : FlipX Series
Standard Model
- FLX-S-ST[Standard]
- FLX-S-DT[Dual technology]
Professional Model
- FLX-P-ST[Standard]
- FLX-P-DT[Dual technology]
Advanced Model
- FLX-A-AM[Active IR anti-masking]
- FLX-A-DAM[Dual technology with active IR anti-masking]
Standard Model
-12 m (40 ft.) 85 degree Wide
-18 m (60 ft.) Narrow
• FLX-S-DT-X5 : 10.525 GHz
• FLX-S-DT-X8 : 10.587 GHz
• FLX-S-DT-X9 : 9.425 GHz
Professional Model
-15 m (50 ft.) 85 degree Wide
-24 m (80 ft.) Narrow
• FLX-P-DT-X5 : 10.525 GHz
• FLX-P-DT-X8 : 10.587 GHz
• FLX-P-DT-X9 : 9.425 GHz
Advanced Model
-15 m (50 ft.) 85 degree Wide
-24 m (80 ft.) Narrow
• FLX-A-DAM-X5 : 10.525 GHz
• FLX-A-DAM-X8 : 10.587 GHz
• FLX-A-DAM-X9 : 9.425 GHz
FlipX is the indoor motion detector not only with a lot of highly evaluated features for existing indoor motion detectors but also with know-how obtained from our experiences of outdoor motion detector development.
Specific Feature
Application Examples
Specific Features
Application Examples
Specific Features
Application Examples
Options
Specifications
Coverage
Dimensions
(No MW detection at “Narrow” setting) |
(No MW detection at “Narrow” setting) |
|||||
11 mA (max.) at 12 VDC |
14 mA (max.) at 12 VDC |
11 mA (max.) at 12 VDC |
14 mA (max.) at 12 VDC |
16 mA (max.) at 12 VDC |
21 mA (max.) at 12 VDC |
|
(with Bracket : Wall, Corner, Ceiling) |
||||||
* Specifications and designs are subject to change without prior notice.
* These units are designed to detect an intruder and activate an alarm control panel. Being only a part of a complete system, we cannot accept responsibility for any damages or other consequences resulting from an intrusion.
* Advanced models (FLX-A-AM and FLX-A-DAM) are certified to NF&A2P when operation temperatures are -10℃ to +55℃(14°F to +131°F).
Standard Model
- The dotted line indicates the recommended mounting height.
- When “Narrow” is selected at the jumper pin, MW detection will be stopped.
- Narrow area settings are not certified to the following standards.EN 50131-2-2:2017(FLX-S-ST)/EN 50131-2-4:2020, INCERT and SBSC.
Advanced and Professional Model
- The dotted line indicates the recommended mounting height.
- When“Narrow”is selected in the lens setting, MW detection will be stopped.
- Down zone * can be deleted by switch setting.
- Narrow area setting of FLX-A-DAM is not certified to NF&A2P.
- Narrow area settings are not certified to the following standards.EN 50131-2-2 (FLX-P-ST)/EN 50131-2-4 (FLX-P-DT), INCERT and SBSC
Standard and Professional Model
Advanced Model
Unit(mm)
Contact phone number
- Headquarters
- +81-77-579-8004
Contact form
Support information