With long, narrow detection areas that extend from both its sides the BX-80N is specifically designed to be wall-mounted centrally on a building, covering the building perimeter with a multi-layered, horizontal barrier that detects intruders before they break in. To help reduce false activations, the range can be adjusted so that detection extends only to the end of the building. The unit also has a size-judging function, which helps it discriminate between large and small objects within the detection area.

The BX-80N is stylishly designed to blend in with any architecture and is simple to install and set up - there being no need to align transmitters and receivers.

Features

  • Double conductive shielding
  • Advanced temperature compensation
  • Limited detection range function
  • Size judging function to avoid false alarms
  • Variable detection range up to 24 m (12 m on each side)
  • Audible alarm indicator to deter intruders (BX-80N only)
  • Attractive, slender design
  • Compatible with numerous wireless transmitters (BX-80N only)
  • Battery saving circuit (BX-80N only)

Size judging function


The BX-80N/80NR only triggers alarms when both upper and lower detection layers detect movements.

Advanced temperature compensation


The BX-80N/80NR uses advance temperature compensation to automatically increase the detector's sensitivity under high temperature conditions, especially where the background temperture ranges from 35 - 37 degree C, close to that of the human body.

Double conductive shielding


By using our double conductive shielding, the visible light disturbance and RFI can be blocked.

Options

Please go to the support page to get the necessary files in PDF and/or DXF.

  • Coverages

  • Specifications

  • Dimensions

Coverages
Model BX-80N BX-80NR
Detection method Passive infrared
Coverage 24 m (12 m on each side)
Detection zones 4 zones (2 zones on each side)
Detectable speed 0.3 m - 2.0 m/s 0.3 m - 1.5 m/s
Sensitivity 1.6°C (3°F) at 0.6 m/s 2.0°C (3.6°F) at 0.6 m/s
Power input 10 - 28 VDC 3 - 9 VDC lithium or alkaline Battery
Current draw 38 mA (max.) 3 mA (Walktest, LED on), 15 µA (Standby)
Alarm period 2.0 ±1 sec
Warm-up period Approx. 45 sec. (LED blinks) Approx. 120 sec. or 5 sec.
Alarm output 2 relay outputs N.O. and N.C. 28 VDC 0.2 A (max.) each Form C-Solid state switch: 10 VDC 0.01 A
Battery saving time - Approx. 120 sec. or 5 sec.
Tamper output N.C. opens when cover is removed Form C activates when cover is removed
Volume of audible alarm Approx. 70 dB (at 1 meter distance) -
LED indicator LED is blinking during warm-up period, Alarm condition Disable during normal operation, Enable during walktest or LED switch on
RF Interference No alarm 20 V/m
Operating temperature -20°C to +50°C
Environment humidity 95% max.
International protection IP55
Mounting Wall
Mounting height 0.8 m - 1.2 m
Weight 400 g 520 g
Accessories 232.7 mm x 55 mm x 68.7 mm 235 mm x 56 mm x 128 mm