Indoor Recessed Mount PIR Detector : AP-360B/20NB

 Indoor Recessed Mount PIR Detector : AP-360B/20NB

360-degree PIR

  • AP-360B(C)[Wired model]
  • AP-360BR(C)[Battery operated]

Curtain PIR

  • AP-20NB(C)[Wired model]
  • AP-20NBR(C)[Battery operated]

Battery operated models are available at limited regions

The AP-360B/20NB is a series of recessed mount indoor PIR detectors.
AP-360B provides a 360-degree volumetric detection area. AP-20NB provides a 20 ft. (6m) curtain area.

These detectors can offer low profile installation for various application scenes.

Features

  • Compact and Discreet design
  • Detection Sensitivity : High,Medium and Low
  • Tamper function
  • Light Control Option (AP-360B only)
  • Battery Saving Timer (Battery Operated Models only)

Spot Detection Patterns (Ceiling or Wall Mount)

Recessed or 86-type box mount installation

Please go to the support page to get the necessary files in PDF and/or DXF.

  • Coverage

  • Specifications

  • Dimensions

Coverage ap-360b
Coverage ap-20nb
Coverage ap-20nb wall
 
Model
AP-360B(C)
AP-360BR(C)
AP-20NB(C)
AP-20NBR(C)
Detection method
Passive infrared
Detection area
ø6 m (ø20’) at mounting height:4.5 m (14’9”)
< Ceiling mount >
6.0 m x 1.0 m (20’ x 3’3”) at 4.5 m (14’9”) height

< Wall mount >
6.0 m x 4.5 m (20’ x 14’9”) at 1.5 m (4’11”) height
Mounting type
Recessed ceiling mount
86-type box mount
Recessed ceiling mount
86-type box mount
Sensitivity
2.0℃ at 0.6 m/s (3.6°F at 2’/s)
Detection speed
0.3 to 3.0 m/s (1’/s to 9’10”/s)
LED indicator
Warm-up upon power on: blinking
Stand-by: off
Alarm: solid on
Warm-up upon power on: blinking
Stand-by: off
Walk test: solid on
Alarm: off
Warm-up upon power on: blinking
Stand-by: off
Alarm: solid on
Warm-up upon power on: blinking
Stand-by: off
Walk test: solid on
Alarm: off
Alarm cycle
2 s to 120 s (variable)
Approx. 2 s
Illuminance
20 to 320 lux (variable/not detected)
-
Battery saving timer
-
120 s/ 5 s selectable
-
120 s/ 5 s selectable
Alarm output
N.O./N.C., 28 V DC 200 mA max.
N.O./N.C., 3.6 V DC 10 mA max.
N.O./N.C., 28 V DC 200 mA max.
N.O./N.C., 3.6 V DC 10 mA max.
Tamper switch
N.C. 28 V DC 100 mA max.
The contact opens once the casing is detached.
Warm-up time
Approx. 60 s
Power supply
9.5 to 16 V DC
2.7 to 3.6 V DC (CR123A battery)
9.5 to 16 V DC
2.7 to 3.6 V DC (CR123A battery)
Current
12 V DC
Stand-by: 11mA, Max.: 13 mA
3 V DC
Stand-by: 10μA, Max.: 4 mA
12 V DC
Stand-by: 11mA, Max.: 13 mA
3 V DC
Stand-by: 10μA, Max.: 4 mA
PIR sensitivity
H / M / L
Weight
50 g (1.76 oz)
Operation temperature
-20 to +50℃ (-4°F to +122°F)
Operation humidity
< 95%
Location
Indoors
Dimensions
< without switch box mount >
ø52 x 42.5 mm (ø2.05 in. x 1.67 in.)

< with 86-type box mount >
86 x 86 x 42.5 mm (3.39 x 3.39 x 1.67 in.)
< without switch box mount >
ø52 x 35.5 mm (ø2.05 in. x 1.40 in.)

< with 86-type box mount >
86 x 86 x 36.5 mm (3.39 x 3.39 x 1.44 in.)

* Specifications and design are subject to change without prior notice.
* These units are designed to detect an intruder and activate an alarm control panel. Being only a part of a complete system, we cannot accept responsibility for any damages or other consequences resulting from an intrusion.

Dimensions

Unit(mm)

Contact phone number

Headquarters
+81-77-579-8004

Support information