Combination sensor OAM-DUAL T

 Combination sensor OAM-DUAL T
  • OAM-DUAL T

Activation&Safety
CE, EN

Color variations

  • ブラック
    Black

The OPTEX OAM-DUAL series is the new sensor standard for use on sliding doors based on a combination of active infrared technology and microwave. The OAM-DUAL series provides safety around the door and through the threshold while the redundant microwave simultaneously ensures a comfortable opening is guaranteed at all times.
The OAM-DUAL series of products comply with the latest European and local regulations as EN 16005 and DIN 18650:2010 and have been safety-tested and approved by the German test organization TÜV.

Features

  • BLUEZONE™ Technology
    When a person or object is detected in the approach area, the sensor activates the door and turns on the BLUEZONE™ that detects through the threshold. The sensor holds the door in the open position for as long as someone remains in the detection area. Once the area is clear, the BLUEZONE™ ignores the door panels and allows the door to safely close.
    This row is automatically shut off once the whole of the presence detection area has cleared and as soon as the doors start to close. The installation of safety beams is no longer mandatory. The OPTEX OAM-DUAL series has been safety-tested and approved by the German test organization TÜV in compliance with the German DIN 18650:2010 and European Norm EN 16005.
  • Motion Detection
    The large microwave motion detection area provides rapid detection of any traffic, approaching from any angle, which allows the door to open conveniently. The presence and motion detection areas can be adjusted independently. By selecting a dipswitch the active infrared detection area can be set to safety only or to safety and activation. The uni-directional function allows the door to close faster when traffic is moving away from the door, contributing to significant energy saving.
  • Easy Installation
    Installation time can be minimized using the easily set switches and shutters, meaning the sensor can be quickly adjusted for many different applications. The use of an OPTEX Infrared finder is recommended to adjust the presence detection area.

Please go to the support page to get the necessary files in PDF and/or DXF.

  • Detection Area

  • Specifications

  • Dimensions

OAM-DUAL T

AIR emitting area
The chart shows the values at depth angle +6°

mm (feet, inch)
Mounting height A 2000 (6'7'') 2200 (7'3'') 2500 (8'2'') 2700 (8'10'') 3000 (9'10'') 3500 (11'6'')
B 50 (2'') 60 (2'') 70 (3'') 74 (3'') 80 (3'') 90 (4'')
C 70 (3'') 80 (3'') 90 (4'') 100 (4'') 110 (4'') 120 (5'')
D 230 (9'') 250 (10'') 280 (11'') 310 (1') 340 (1'1'') 390 (1'3'')
E 350 (1'2'') 390 (1'3'') 440 (1'5'') 480 (1'7'') 530 (1'9'') 610 (2')
F 590 (1'11'') 650 (2'2'') 740 (2'5'') 800 (2'7'') 890 (2'11'') 1030 (3'5'')
G 1210 (3'12'') 1330 (4'4'') 1510 (4'11'') 1630 (5'4'') 1810 (5'11'') 2110 (6'11'')
H 1860 (6'1'') 2050 (6'9'') 2320 (7'7'') 2510 (8'3'') 2790 (9'2'') 3250 (10'8'')
I 2520 (8'3'') 2780 (9'1'') 3150 (10'4'') 3400 (11'2'') 3790 (12'5'') 4420 (14'6'')

AIR detection area
To comply with EN 16005, make sure that the detection area is within the values of the chart below.

A 2000 (6'7'') 2200 (7'3'') 3000 (9'10'')
X 230 (9'') 250 (10'') 340 (1'1'')
G 1020 (3'4'') 1120 (3'8'') 1530 (5')
I * 2410 (7'11'') 2650 (8'8'') 3600 (11'10'')

Test conditions required by EN 16005
Floor: Grey paper
Detection object: EN 16005 CA reference body
Sensitivity: Middle
Speed of detection object: 50 mm/sec.

The values above are those of the AIR detection area when tested referring to the test conditions of EN 16005.
(The emitting area is as shown in AIR emitting area above.)
* When installed at higher than 3.0 m (9'10") , EN 16005 requirements are fulfilled only within the area width "I" of 3.6 m (11'10") .

* The actual detection area may become smaller depending on the ambient light, the color/material of the object or the floor as well as the entry speed of the object.
* The sensor may not be activated when the entering speed of the object or a person is slower than 50 mm/sec. or faster than 1500 mm/sec.

Model OAM-DUAL T
Cover color Black
Mounting height 2.0 to 3.5 m (6'7'' to 11'6'')
Detection area See Detection area
Detection method Active infrared reflection (*1)
Microwave doppler effect
Transmitter frequency 24.125GHz
Transmitter radiated power < 20dBm
Depth angle adjustment AIR area -6° to +6°
Microwave area +25° to +45°
Power supply (*2) 12 to 24VAC ±10% (50 / 60Hz)
12 to 30VDC ±10%
Power consumption < 2.5W (< 4VA at AC)
Output hold time < 0.5sec.
Response time < 0.3sec.
Operating temperature -20°C to +55°C (-4°F to 131°F)
Operating humidity < 80%
Noise level < 70dBA
Activation input Opto coupler
Voltage 5 to 30VDC
Current 6mA Max. (30VDC)
Safety input Opto coupler
Voltage 5 to 30VDC
Current 6mA Max. (30VDC)
Safety output Opto coupler (NPN)
Voltage 5 to 50VDC
Current 100mA Max.
Dark current 600nA Max. (Resistance load)
IP rate IP54
ESPE Type 2
Weight 270g (9.5oz)
Accessories 1 Operation manual
2 Mounting screws
1 Mounting template
1 Area adjustment tool
1 Cable 3m (9'10'') (8×0.22mm2 AWG24) (*3)

*1 Active infrared reflection has a presence detection function.
*2 The sensor has to be connected to a door system which has a SELV circuit.
*3 Overcurrent protection with less than 2 A.