Active infrared sensor OA-AXIS T

 Active infrared sensor OA-AXIS T
  • OA-AXIS T(S)
  • OA-AXIS T(BL)

Activation & Safety
CE, EN

Color variations

  • シルバー
    Silver
  • ブラック
    Black

The OPTEX OA-AXIS T is the new automatic door standard for use on sliding doors based on the active infrared technique. The OA-AXIS T has been developed as a combination sensor for threshold safety and activation. The OA-AXIS T complies with the latest European and local regulations as EN 16005 and DIN 18650, tested and approved by the German test organization TÜV. Due to its variety of output options, the OA-AXIS T meets the requirements in various markets.

Features

  • Combination
    The OPTEX OA-AXIS T is the world’s first door sensor based solely on the active infrared technique, combining activation and safety in one sensor. By using the unique OPTEX presence detection technique, the OA-AXIS T ensures maximum safety around the threshold while simultaneously providing a large motion detection area for the door activation.
  • Safety
    The active infrared presence detection of the OA-AXIS T can be set very accurately and can be moved 6° toward or away from the door. The installation of safety beams is no longer mandatory. The sensor detects a person or object and holds the door open for as long as they are in or near the threshold area, even if they stop or pause. The OPTEX OA-AXIS T has been tested and approved by the German test organization TÜV and complies with the German DIN 18650 and European Norm EN 16005.
  • Motion detection
    The large detection area provides rapid detection of any traffic, including trolleys, approaching from any angle. The sensor’s enhanced pattern depth enables it to detect people and objects farther away and allows the door to open conveniently for them. The presence and motion detection areas can be adjusted independently.
  • Variety
    By offering different types of output contacts, the OA-AXIS series meets the requirements and local standards in many different markets.
    OA-AXIS I: 1 relay output for activation and safety
    OA-AXIS II: 1 relay for safety and a second relay for motion/activation
    OA-AXIS T: 1 relay for motion and activation and an Opto coupler (NPN) in/output for safety
  • Easy adjustment
    Installation time can be minimized using the easily set switches and shutters, meaning the sensor can be quickly adjusted for many different applications. The use of an OPTEX Infrared finder is recommended to adjust the presence detection area.

Please go to the support page to get the necessary files in PDF and/or DXF.

  • Detection Area

  • Specifications

  • Dimensions

Emitting area

mm (feet, inch)
Mounting height
A
2000 (6'7'') 2200 (7'3'') 2500 (8'2'') 2700 (8'10'') 3000 (9'10'')
B 130 (5'') 140 (6'') 160 (6'') 180 (7'') 200 (8'')
C 380 (1'3'') 420 (1'5'') 480 (1'7'') 520 (1'8'') 580 (1'11'')
D 740 (2'5'') 820 (2'8'') 930 (3'1'') 1000 (3'3'') 1100 (3'7'')
E 1230 (4') 1350 (4'5'') 1540 (5'1'') 1660 (5'5'') 1850 (6'1'')
F 1740 (5'9'') 1900 (6'3'') 2170 (7'1'') 2340 (7'8'') 2600 (8'6'')
G 1060 (3'6'') 1330 (4'4'') 1510 (4'11'') 1630 (5'4'') 1810 (5'11'')
H 1860 (6'1'') 2050 (6'9'') 2320 (7'7'') 2510 (8'3'') 2790 (9'2'')
I 2520 (8'3'') 2780 (9'1'') 3150 (10'4'') 3400 (11'2'') 3790 (12'5'')
X 190 (7'') 210 (8'') 240 (9'') 260 (10'') 280 (11'')

* X is the distance between the 1st row and the mounting surface.

Detection area
To comply with EN 16005, make sure that the detection area is within the values in the below.

mm (feet, inch)
A 2000 (6'7'') 2200 (7'3'')
C 230 (9'') 240 (9')
G 1020 (3'4'') 1010 (3'7'')
I * 2410 (7'11'') 2540 (8'4'')

Test conditions required by EN 16005
Floor: Grey paper
Detection object: EN 16005 CA reference body
Sensitivity: Middle
Speed of detection object: 50 mm/sec.

* The values above are those of the Detection area when tested referring to the test conditions of EN 16005.
(The emitting area is as shown in Emitting area above.)
* When installed at higher than 2.20 m (7'3") , EN 16005 requirements are fulfilled only within the area width "I" of 2.54 m (8'4") .

* The actual detection area may become smaller depending on the ambient light, the color / material of the object or the floor as well as the entry speed of the object.
* The sensor may not be activated when the entering speed of the object or a person is slower than 50 mm (2'') /sec. or faster than 1500 mm (4'11'') /sec.

Model OA-AXIS T
Cover color Silver, Black
Mounting height 2.0 m to 3.0 m (6'7'' to 9'10'')
Detection area See Detection area
Detection method Active infrared reflection (*1)
Depth angle adjustment 1st to 3rd rows -6° to +6°
4th and 5th rows +26° to +44°
Power supply (*2) 12 to 24VAC ±10% (50 / 60Hz)
12 to 30VDC ±10%
Power consumption < 2.5 W (< 4 VA at AC)
Safety input Opto coupler
Voltage 5 to 30VDC
Current 6mA Max. (30VDC)
Safety output When 1st or 2nd row detects.
Opto coupler (NPN)
Voltage 5 to 50VDC
Current 100mA Max.
Dark current 600nA Max. (Resistance load)
Activation output When 3rd, 4th or 5th row detects.
Form A relay
50V 0.3A Max. (Resistance load)
Operating temperature -20°C to +55°C (-4°F to 131°F)
Operating humidity < 80%
Noise level < 70 dBA
Output hold time < 0.5 sec.
Response time < 0.3 sec.
IP rate IP54
Category 2 (EN ISO 13849-1: 2015)
Performance level d (EN ISO 13849-1: 2015)
ESPE Type 2
Weight 320 g (11.2 oz)
Accessories 1 Operation manual
2 Mounting screws
1 Mounting template
1 Area adjustment tool
1 Cable 3 m (9'10'') (8×0.22mm2 AWG24)

*1 : The 1st and 2nd rows have presence detection function.
*2 : When using this sensor, the sensor has to be connected to a door system which has the SELV circuit.
*3 : Overcurrent protection with less than 2 A.

mm (inch)